Описание оборудования | |
---|---|
Single head system | |
General specifications | |
Sensing range | 200 ... 4000 mm |
Adjustment range | 240 ... 4000 mm |
Dead band | 0 ... 200 mm |
Standard target plate | 100 mm x 100 mm |
Transducer frequency | approx. 85 kHz |
Response delay | approx. 325 ms |
Indicators/operating means | |
LED green | solid green: Power on |
LED yellow | solid: switching state switch output flashing: program function |
LED red | normal operation: "fault" program function: no object detected |
Electrical specifications | |
Operating voltage | 10 ... 30 V DC , ripple10%SS |
No-load supply current | ? 60 mA |
Input/Output | |
Synchronization | bi-directional 0 level -UB...+1 V 1 level: +4 V...+UB input impedance: > 12 KOhm synchronization pulse: ? 100 µs, synchronization interpulse period: ? 2 ms |
Synchronization frequency | |
Output | |
Output type | 1 switching output E5, PNP NO/NC, programmable |
Rated operating current | 200 mA , short-circuit/overload protected |
Default setting | Switch point A1: 240 mm , Switch point A2: 4000 mm , wide sound lobe |
Voltage drop | ? 2.5 V |
Repeat accuracy | ? 0.5 % of switching point |
Switching frequency | ? 1.2 Hz |
Range hysteresis | 1 % of the set operating distance |
Temperature influence | ± 1 % of full-scale value |
Approvals and certificates | |
UL approval | cULus Listed, General Purpose |
CSA approval | cCSAus Listed, General Purpose |
CCC approval | CCC approval / marking not required for products rated ?36 V |
Ambient conditions | |
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
Mechanical specifications | |
Connection type | Connector M12 x 1 , 5-pin |
Degree of protection | IP54 |
Material | |
Mass | 150 g |
8 (029) 555-8-000 | |
8 (044) 555-8-000 | |
8 (017) 255-8-000 |