Nominal voltage | |
---|---|
Specific value | 24 VDC |
Limit values, min/max | 10/30 VDC |
Nominal current, typically | |
Specific value | 50 mA |
Condition | unloaded |
Supply | |
In case of UL / CSA approval | according to NEC Class 2 |
Device design | |
Type | Single-/Multi-Turn |
Total resolution | <= 36 Bit |
Number of steps per revolution | <= 262144 |
Number of revolutions | <= 256000 |
Output capacity | <= 32 Bit |
Accuracy | ± 1 LSB |
CANopen - Interface | |
CANopen | EN 50325-4 |
Bus connection | ISO 11898-1, ISO 11898-2 |
CAN Specification 2.0 A | 11-Bit Identifier |
Device-Profile for Encoder | CiA DS406 |
Layer Setting Services, LSS | CiA DS305 |
SSI - Interface | |
Equipment | Optional interface |
SSI-Clock input | Optocoupler |
SSI-Data output | RS-422, 2-wire |
Incremental - Interface | |
Equipment | Optional interface |
Incremental signals, square | K1± K2± K0± |
Type of parametrization | programmable |
Transmission rate | |
Specific value | 10, 20, 50, 100, 125, 250, 500 |
Specific value | 800, 1000 kbit/s |
Adjustability | by means of DIP-switches |
Adjustability | via LSS service |
Parameter/Function, changeable | Resolution |
Operating range | |
Download, EDS file | |
Limit switch | |
External Preset inputs | |
Firmware update | |
Node-ID | |
Preset parameter | |
Scaling parameter | |
SSI-Parameter | |
Transmission rate | |
Counting direction | |
Gear function | |
Velocity parameter | |
Number of pulses | |
Phase position: K0/K1/K2 | |
Type of parametrization | programmable |
Programming - Tool | Fieldbus-Device |
External inputs | |
Preset | electronic adjustment |
Type of parametrization | programmable |
Logic level | "0“ < +2V, "1“ = Supply |
Equipment | Option |
Maximum Speed, mechanically | <= 12000 1/min |
Shaft load, axial/radial | <= 50 N, <= 100 N |
Bearing life time | >= 3.9E+10 revolutions |
Bearing life time - Parameter | |
Speed | 6000 1/min |
Operating temperature | 60 °C |
Shaft load, axial/radial | = 60 % |
Point of origin, shaft load | Mounting flange + 10 mm |